  Datasheet File OCR Text:
  features & benefits bandwidths of 15 ghz (tds6154c), 12 ghz (tds6124c), 8 ghz (TDS6804B) and 6 ghz (tds6604b) rise times to 19 ps 20 to 80% (28 ps 10 to 90%) on tds6154c typical rise time, with channel- matched, user-selectable dsp 40 gs/s real-time sample rate on two channels, 20 gs/s real- time sample rate on all four channels with 500 fs/sample interpolated points up to 64 megasamples on two channels, up to 32 megasamples record length on all four channels with multiview zoom function for quick navigation pinpoint triggering provides the most flexible and highest performance triggering, with over 1400 combinations to address virtually any triggering situation serial pattern triggering up to 3.125 gb/s with 8b/10b protocol triggering serial data analysis and compliance at rates of 6.25 gb/s and above openchoice software with windows xp os delivers built-in networking and analysis technology-specific software solutions provide built-in domain expertise for serial data, jitter, ethernet, dvi, usb 2.0, communications and power measurements system includes: dual processor system (2.8 ghz pentium 4 and 583 mhz powerpc), high resolution xga display, front panel cd-r/w, front panel usb 2.0 port, and 1000base-t network connection applications signal integrity, jitter and timing analysis validation, debug, characterization and compliance of next-generation digital designs computer, datacom, storage area network equipment designs and high-speed backplanes high energy physics measurements and data acquisition digital storage oscilloscope tds6000 series uncompromised performance oscilloscope solution ? probing, acquisition, analysis, compliance and debug tds6000 series digital storage oscilloscopes provide unprecedented performance along with a complete feature set designed to address design validation, debug and compliance challenges of next generation computer, datacom and communications equipment. high bandwidth, high sample rate and deep memory also provide the ideal solution for data acquisition applications. uncompromised acquisition you wont need to need to trade off bandwidth, record length and sample rate for your serial data measurement and analysis needs. the tds6000c dsos provide acquisition architecture with 40 gs/s maximum sample rate and 64 megasamples record length on two channels (20 gs/s and 32 megasamples on each of the four channels simultane- ously), for the acquisition power you need. they provide the ultimate combination of bandwidth, sample rate and record length for the fastest signals. the tds6154c provides matched 15 ghz performance across any two channels using advanced, tektronix-proprietary dsp enhancement, important for high-speed channel-to- channel measurements. the user- selectable dsp filter on each channel provides magnitude and phase correction, plus extension of the analog bandwidth to 15 ghz for more accurate signal fidelity on high speed measurements?asily capturing the fifth harmonic of 3.125 ghz embedded clocks used in next-generation 6.25 gb/s serial data standards, and even the third harmonic of 5 ghz clocks being developed for future systems. the dsp filter on each channel can also be switched off to take advantage of true 12 ghz analog bandwidth for applications needing the highest-available raw data capture.
digital storage oscilloscope tds6000 series digital storage oscilloscopes ?www.tektronix.com/oscilloscopes 2 pinpoint triggering the ability to trigger an oscilloscope on events of interest is paramount in high- speed debug and validation. whether you?e trying to find a system error or need to isolate a section of a complex signal for further analysis, tektronix pinpoint triggering provides the solution. the pinpoint trigger system uses silicon germanium (sige) technology to provide trigger sensitivity of up to 9 ghz (tds6000c models) and allows selection of all trigger types on both a and b trigger circuits. it can capture glitches down to 100 ps wide with trigger jitter less than 1.3 ps rms (tds6000c models). other trigger systems offer multiple trigger types only on a single event (a event), with delayed trigger (b event) selection limited to edge type triggering and often does not provide a way to reset the trigger sequence if the b-event doesnt occur. but pinpoint triggering provides the full suite of advance trigger types on both a and b triggers with reset triggering to begin the trigger sequence again after a specified time, state or transition so that even events in the most complex signals can be captured. other oscilloscopes typically offer less than 20 trigger combinations; pinpoint triggering offers over 1400 combinations, all at full performance. protocol triggering and decoding software (opt. ptd) easily decode 8b/10b and other encoded serial data streams and set desired encoded words for the serial pattern trigger to capture. the tds6000c models can trigger on up to four consecutive 10-bit words or specified err or conditions at data rates up to 3.125 gb/s. and you can see the captured bit sequences decoded into their words for convenient analysis. unparalleled analysis waveform data analysis can take many forms. whether its a simple math expres- sion, waveform mask testing, a pass/fail compliance test, or a custom application that you develop, the tds6000 series offers the industrys most comprehensive set of analysis and compliance tools. built-in analysis tools standard tools built into the tds6000 offer a wide range of analysis capabilities including cursors, measurements, math equation editor, serial data communications mask testing (with opt. sm), and spectrum analysis. trigger on glitches down to 100 ps wide. decode 8b/10b data streams and set up to 4 data words (40 bits) to trigger on. waveform math equation editor. enables boundless analysis on waveform data. 8.5 gb/s tdsrt-eye diagram on the tds6154c. pinpoint trigger system provides the most advanced, highest performance triggering available. measurement system. enables over 50 parametric measurements in the amplitude, time and statistical domain.
digital storage oscilloscope tds6000 series digital storage oscilloscopes ?www.tektronix.com/oscilloscopes 3 technology-specific software solutions validation, debug and compliance testing often require automated test tools that quickly analyze waveform data and provide the answers you need. the tds6000 models provide complete ?urnkey?solutions for the most demanding technologies. software options are also available for performing validation and compliance measurements on emerging industry standards. openchoice analysis designing your own custom solution? the analysis and networking features of openchoice software adds more flexibility to tektronix open windows xp oscillo- scopes: fast, pci bus speed communication between the data acquisition processor and the microsoft windows desktop. activex controls to connect the oscilloscope to popular windows applications ?without leaving the application. pnp drivers to control the scope from labview and lab windows/cvi running directly on the oscilloscope, or running on external pcs. support for application development environments includes visual basic, .net, c, c++, matlab, labview and labwindows/cvi. tdsjit3 v2.0 jitter analysis for validation and debug high speed digital systems. tdsdvi digital visual interface compliance. tdsrt-eye software. compliance and analysis for testing high speed serial standards. eye diagrams at data rates to beyond 6.25 gb/s. software clock recovery to 10 gb/s. tdset3 10/100/1000base-t compliance. access data seamlessly for your own custom application, such as this excel example.
digital storage oscilloscope tds6000 series differential probing with performance to >12 ghz most high speed signals today are differ- ential. the p7313 12.5 ghz differential probing system provides true differential connection to the device under test for a variety of connection requirements: solder-in, hand held, and fixtured. typical system performance with the tds6000c models exceeds 12 ghz bandwidth. the p7313 offers the lowest loading, highest signal fidelity, and lowest cost per connection in the industry. versatile, inex- pensive tip-clip tm adapters provide the optimum solution for virtually any connec- tion need. the p7380sma differential probing system provides a 50 ? per side termina- tion network with a termination voltage. the termination voltage can be applied externally or through the tekconnect interface from the tds6000 probe menu, or not used at all. a gain switch provides two different sensitivity settings of the probe and an aux out provides an inverted version of the signal for driving other equipment. the p7380sma probing system used with the tds6000 oscilloscopes provides an ideal solution for validation and compliance testing of high speed serial data links. digital storage oscilloscopes ?www.tektronix.com/oscilloscopes 4 p7313 12.5 ghz differential probe.
digital storage oscilloscopes ?www.tektronix.com/oscilloscopes 5 digital storage oscilloscope tds6000 series characteristics vertical system tds6604b TDS6804B tds6124c tds6154c input channels 4 4 4 4 bandwidth, rise time (dsp) n/a 8 ghz 12 ghz 15 ghz 50 ps (10 to 90%) (typical) 35 ps (10 to 90%) (typical) 28 ps (10 to 90%) (typical) 35 ps (20 to 80%) (typical) 24 ps (20 to 80%) (typical) 19 ps (20 to 80%) (typical) true analog bandwidth 6 ghz 7 ghz 12 ghz 12 ghz (? db), typical rise time 70 ps (10 to 90%) (typical) 62 ps (10 to 90%) (typical) 35 ps (10 to 90%) (typical) 35 ps (10 to 90%) (typica l) 53 ps (20 to 80%) (typical) 43 ps (20 to 80%) (typical) 24 ps (20 to 80%) (typical) 24 ps (20 to 80%) (typical) hardware bandwidth limits full, 250 mhz or 20 mhz (requires tca-1 meg adapter) input coupling dc, gnd input impedance 50 ? ?.5% 50 ? ?% input sensitivity, 50 ? full scale 100 mv to 10 v (10 mv/div to 1 v/div). full scale 100 mv to 10 v (5 mv/div *1 to 1 v/div). full scale is the peak-to-peak digitizer full scale is the peak-to-peak digitizer range at a given sensitivity. range at a given sensitivity. volts/div = full scale 10 volts/div = full scale 10 vertical resolution 8-bit (>11-bit with averaging) max input voltage, 50 ? <1 v rms for <100 mv/div, <1 v rms for <1 v full scale, <7 v rms for 100 mv/div settings. <7 v for 1v full scale. also determined by tekconnect accessory also determined by tekconnect accessory dc gain accuracy ?2.5% + (2% x offset)) ?% position range ? divisions offset range *2 full scale settings: full scale settings: 100 mv to 500 mv: 0.5 v 100 mv: 0.45 v 505 mv to 995 mv: 0.25 v 200 mv: 0.4 v 1 v to 5 v: 5 v 500 mv: 0.25 v 5.05 v to 10 v: ?.5 v 1 v: ?.5 v 2v:4.0v 5v:2.5v 10 v: 0 general formula for offset range 100 mv to 995 mv: ?0.5v - full scale/2| 1 v to 10 v: ?5v - full scale/2| offset accuracy ?0.5% of channel offset + 15 mv + 0.1 div x v/div setting) for ranges >100 mv/div channel-to-channel isolation 80:1 at 1.5 ghz and 15:1 at rated bandwidth 80:1 at 10 ghz and 30:1 at 12 ghz for any two channels at equal vertical scale noise (analog only, dsp turned off) full scale settings: (when zoom is turned off, divide by 10 for volts/div) 100 mv: 600 ? rms 200 mv: 970 ? rms 500 mv: 2.3 mv rms 1v:5.9mv rms 2v:9.7mv rms 5 v: 22.5 mv rms 10 v: 47.7 mv rms *1 5 mv/div is a sw zoom with 20 divisions across the full scale range. *2 offset range in addition to ? division position range.
digital storage oscilloscope tds6000 series digital storage oscilloscopes ?www.tektronix.com/oscilloscopes 6 timebase system all models timebase range 25 ps to 40 s/div; interpolation down to 500 fs/pt timebase delay time range 5 ns to 250 s channel-to-channel deskew range ?5 ns trigger jitter (rms) tds6000c models <1.1 ps rms (typical) tds6000b models <1.5 ps rms (typical) long-term sample rate and delay time accuracy 2.5 ppm over any 100 ms interval clock stability <1 ppm (typical) <2.5 ppm (guaranteed) jitter noise floor 420 fs rms (typical) over 2 ? duration or less delta time accuracy 635 fs rms over <100 ns duration, single shot acquisition system tds6000b models tds6000c models max sample rate 20 gs/s on 4 channels 40 gs/s on 2 channels, 20 gs/s on 4 channels equivalent time sample rate (max) 2 ts/s maximum record length per channel 32 m (requires opt. 4m) 64 m on two channels; 32 m on all 4 channels (requires opt. 4m) standard 2 m on all 4 channels 4 m on two channels; 2 m on all 4 channels with memory opt. 2m 8 m on all 4 channels 16 m on two channels; 8 m on all 4 channels with memory opt. 3m 16 m on all 4 channels 32 m on two channels; 16 m on all 4 channels with memory opt. 4m 32 m on all 4 channels 64 m on two channels; 32 m on all 4 channels maximum time duration captured at highest real-time resolution (all channels) tds6000b models tds6000c models (all channels) (two channels) max duration with standard memory 100 ? 100 ? max duration with opt. 2m 400 ? 400 ? max duration with opt. 3m 800 ? 800 ? max duration with opt. 4m 1.6 ms 1.6 ms
digital storage oscilloscopes ?www.tektronix.com/oscilloscopes 7 digital storage oscilloscope tds6000 series acquisition modes all models waveform database accumulate waveform database providing three-dimensional array of amplitude, time and counts sample acquire sampled values peak detect captures narrow glitches at all real-time sampling rates minimum peak detect pulse width 50 ps averaging from 2 to 10,000 waveforms included in average envelope from 2 to 2x10 9 waveforms included in min-max envelope hi-res real-time boxcar averaging reduces random noise and increases resolution fastframe tm acquisition acquisition memory divided into segments; maximum trigger rate >310,000 waveforms per second. time of arrival recorded with each event roll mode 200 ks/s at 8 m record length and 500 ks/s at 4 m record length on all channels pinpoint trigger system all models sensitivity internal dc coupled 0.5 div dc to 50 mhz increasing to 2.5 div at 7 ghz (tds6000b models, typical), 4 div at 9 ghz (tds6000c models, typical) external (auxiliary input) 200 mv from dc to 50 mhz increasing to 500 mv at 2 ghz trigger characteristics main trigger modes auto, normal and single a event & delayed b event trigger types edge, glitch, runt, width, transition time, timeout, pattern, state, setup/hold, window? all except edge, pattern and state can be logic state qualified by up to two channels trigger sequences main, delayed by time, delayed by events, reset by time, reset by state, reset by transition. all sequences can include separate horizontal delay after the trigger event to position the acquisition window in time communications-related triggers support for ami, hdb3, bnzs, cmi, mlt3 and nrz encoded communications (requires opt. sm) signals up to 3.125 gb/s. select among isolated positive or negative one, zero pulse form or eye patterns as applicable to standard serial pattern trigger 64-bit serial word recognizer, bits specified in binary (high, low, don? care) (requires opt. st) or hex format. trigger on nrz-encoded data up to 1.25 gbaud. tds6000c models only: trigger on encoded data up to 3.125 gbaud (40 bits) trigger level range internal ?2 divisions from center of screen external (auxiliary in) ? v line fixed at 0 v trigger coupling dc, ac (attenuate <60 hz), hf reject (attenuate >30 khz) lf reject (attenuates <80 khz) noise reject (reduce sensitivity) trigger holdoff range 250 ns minimum to 12 s maximum
digital storage oscilloscope tds6000 series trigger types edge ? positive and/or negative slope on any channel or front panel auxiliary input. coupling includes dc, ac, noise reject, hf reject and lf reject. glitch trigger on or reject glitches of positive, negative or either polarity. minimum glitch width is down to 100 ps with rearm time of 250 ps. width ? trigger on width of positive or negative pulse (down to 100 ps) either within or out of selectable time limits. runt ? trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again. optional time qualification. timeout ? trigger on an event which remains high, low or either, for a specified time period, selectable from 360 ps to 1 s. transition ? trigger on pulse edge rates that are faster or slower than specified. slope may be positive, negative or either. setup/hold ? trigger on violations of both setup time and hold time between clock and data present on any two input channels. pattern trigger when pattern goes false or stays true for specified period of time. pattern (and, or, nand, nor) specified for four input channels defined as high, low or don? care. state ? any logical pattern of channels (1, 2, 3) clocked by edge on channel 4. trigger on rising or falling clock edge. window trigger on an event that enters or exits a window defined by two user-adjustable thresholds. event can be time or logic qualified. trigger delay by time ? 5 ns to 250 seconds. trigger delay by events ? 1 to 10,000,000 events. waveform measurements amplitude ? amplitude, high, low, maximum, minimum, peak-to-peak, mean, cycle mean, rms, cycle rms, positive overshoot, negative overshoot. time ? rise time, fall time, positive width, negative width, positive duty cycle, negative duty cycle, period, frequency, delay. combination ? area, cycle area, phase, burst width. histogram-related ? waveform count, hits-in- box, peak hits, median, maximum, minimum, peak-to-peak, mean (?, standard deviation ( ), ? 1 ,+ 2 ,+ 3 . eye pattern-related ? extinction ratio (absolute, %, and db), eye height, eye top, eye base, eye width, crossing %, jitter (peak-to-peak, rms and 6 ), noise (peak-to-peak and rms), s/n ratio, cycle distortion, q-factor. waveform processing/math algebraic expressions ? define extensive algebraic expressions including waveforms, scalars and results of parametric measurements e.g. (integral (ch.1?ean(ch.1)) x 1.414). arithmetic ? add, subtract, multiply, divide waveforms and scalars. relational ? boolean result of comparison >, <, , ,=, . calculus ? integrate, differentiate. frequency domain functions ? spectral magnitude and phase, real and imaginary spectra. vertical units ? magnitude: linear, db, dbm; phase: degrees, radians. window functions ? rectangular, hamming, hanning, kaiser-bessel, blackman-harris, gaussian, flattop2, tek exponential. waveform definition ? as arbitrary math expressions. display characteristics display type ? liquid crystal active-matrix color display. display size ? diagonal: 264 mm (10.4 in.). display resolution ? 1024 horizontal x 768 vertical pixels. waveform styles ? vectors, dots, variable persistence, infinite persistence. computer system and peripherals cpu ? intel pentium 4 processor, 2.8 ghz. pc system ram ? 1 gb (266 mhz ddr). hard disk drive ? 40 gb removable hard disk drive: rear-panel standard or front-panel (opt fhd). usb ports ? one front panel, four on rear panel, usb 2.0 compliant. cd-r/w drive ? front-panel cd-r/w standard or rear-panel (opt. fhd). mouse ? optical scroll wheel model included, usb interface. keyboard small keyboard included (fits in pouch). order 119-6297-xx for full-size keyboard; usb interface and hub. input/output ports front panel fast edge output ? front panel sma connector provides fast edge signal. amplitude 350 mv ?0% into a 50 ? load, frequency 1 khz ?%, 200 ps typical rise time. recovered clock sma connector, 1.25 gb/s, output swing 130 mv pk-pk into 50 ? . requires opt. sm or opt. st to enable. recovered data ? sma connector, 1.25 gb/s, output swing of 1010 repeating pattern 200 mv into 50 ? . requires opt. sm or opt. st to enable. dc probe calibration output ? bnc connector, ?0 v dc for dc probe calibration. (signal available only during probe calibration.) aux trigger output ? bnc connector, provides a ttl-compatible, polarity switchable pulse when the oscilloscope triggers. usb 2.0 port ? one in front. allows connection or disconnection of usb keyboard, mouse or storage device while oscilloscope is on. digital storage oscilloscopes ?www.tektronix.com/oscilloscopes 8
digital storage oscilloscopes ?www.tektronix.com/oscilloscopes 9 digital storage oscilloscope tds6000 series rear panel external time base reference in ? bnc connector; allows time base system to phase-lock to external 10 mhz reference. time base reference out ? bnc connector; provides ttl-compatible output of internal 10 mhz reference oscillator. aux trigger input ? bnc, see ext trigger specification. parallel port ? ieee 1284, db-25 connector. audio ports ? miniature phone jacks for stereo microphone input and stereo line output. usb 2.0 ports ? four in back. allows connection or disconnection of usb keyboard, mouse or storage device while oscilloscope power is on. keyboard port ? ps-2 compatible. mouse port ? ps-2 compatible. lan port ? rj-45 connector, supports 10base-t, 100base-t, and 1000base-t. serial port ? db-9 com1 port. windows video port ? 15 pin d-sub connector on the rear panel; connect a second monitor to use dual-monitor display mode allowing analysis results and plots to be viewed along with the oscilloscope display. video is ddc2b compliant. gpib port ? ieee 488.2 standard. scope xga video port ? 15 pin d-sub connector on the rear panel, video is ibm xga compatible. connect to show the oscilloscope display, including live waveforms on an external monitor or projector. the primary windows desktop can also be displayed on an external monitor using this port. power source power ? 100 to 240 v rms , 10%, 50/60 hz; 115 v rms ?0%, 400 hz; cat ii, <500 w typical (650 va). option sm 156 standards masks supported ? itu-t (1.544 mb/s to 155 mb/s). ansi t1.102 (1.544 mb/s to 155 mb/s). ethernet ieee std 802.3, ansi x3.263 (1.544 mb/s ?3.125 gb/s xaui). sonet/sdh (51.84 mb/s to 2.4883 gb/s). fibre channel (133 mb/s to 4.25 gb/s *3 ). infiniband (2.5 gb/s). usb (12 mb/s to 480 mb/s). serial ata (1.5 gb/s, 3.0 gb/s). serial attached scsi (1.5 gb/s, 3.0 gb/s). ieee 1394b (491.5 mb/s to 1.966 gb/s). rapidi/o (1.25 gb/s to 3.125 gb/s). oif standards (2.488 gb/s to 3.11 gb/s). pci express (2.5 gb/s). physical characteristics benchtop configuration dimensions mm in. height 282 11.1 width 457 18.0 depth 540 23.25 weight kg lb. net 21 47 shipping 32.3 71.2 rackmount configuration dimensions mm in. height 267 10.5 width 491 19.3 depth 638 25.1 weight kg lb. net 22 49 kit 5.6 12.25 mechanical cooling ? required clearance mm in. top 0 or >76 0 or >3 bottom 25 1 left side 76 3 right side 76 3 front 0 0 rear 0 0 *3 4.25gb/s mask supported using glitch trigger. environmental temperature operating ? +5 ? to +50 ?, excluding cd-r/w drive; +10 ? to +45 ?, including cd-r/w drive. nonoperating ? ?2 ? to +60 ?. humidity operating ? 20% to 80% relative humidity with a maximum wet bulb temperature of +29 ? at or below +50 ?, noncondensing. upper limit derated to 25% relative humidity at +50 ?. nonoperating ? 5% to 90% relative humidity with a maximum wet bulb temperature of +29 ? at or below +60 ?, noncondensing. upper limit derated to 20% relative humidity at +60 ?. altitude operating ? 10,000 ft. (3,048 m). nonoperating ? 40,000 ft. (12,190 m). random vibration operating ? 0.000125 g 2 /hz from 5 to 350 hz, ? db/octave from 350 to 500 hz, 0.0000876 g 2 /hz at 500 hz. overall level of 0.24 g rms . nonoperating ? 0.0175 g 2 /hz from 5 to 100 hz, ? db/octave from 100 to 200 hz, 0.00875 g 2 /hz from 200 to 350 hz, ? db/octave from 350 to 500 hz, 0.006132 g 2 /hz at 500 hz. overall level of 2.28 g rms . certifications electromagnetic compatibility ? 89/336/eec. safety ? ul 3111-1, csa1010.1, en61010-1, iec 61010-1.
digital storage oscilloscope tds6000 series ordering information tds6154c 15 ghz digital storage oscilloscope. tds6124c 12 ghz digital storage oscilloscope. TDS6804B 8 ghz digital storage oscilloscope. tds6604b 6 ghz digital storage oscilloscope. tds6000b and tds6000c models include: accessory pouch, front cover, usb mouse, ps2 mini-keyboard, user manual (071-1503-xx), quick reference kit (020-2552-xx), documentation cd- rom (063-3760-xx), product software cd-rom (063-3761-xx), operating system restoration cd- rom (063-3762-xx), optional applications software cd-rom (063-3478-xx), performance verification procedure pdf file, gpib programmers reference (on product software cd-rom), calibration certifi- cate documenting nist traceability, 2 540-1 compliance and iso9000, power cord, one year warranty. (4) tekconnect to sma adapters (tca-sma), deskew fixture (067-0484-xx). please specify power plug when ordering. instrument options power plug options opt. a0 north america power. opt. a1 universal euro power. opt. a2 united kingdom power. opt. a3 australia power. opt. a5 switzerland power. opt. a6 japan power. opt. a10 china power. opt. a99 no power cord or ac adapter. disk drive options opt. fhd front-panel 40 gb removable hard disk drive, replaces front panel cd-r/w which is moved to the back. cables gpib cable (1 m) order 012-0991-01. gpib cable (2 m) order 012-0991-00. rs-232 cable order 012-1298-00. centronics cable order 012-1214-00. mounting options 1k k4000 oscilloscope cart. 1r rackmount kit. service options opt. c3 calibration service 3 years. opt. c5 calibration service 5 years. opt. d1 calibration data report. opt. d3 calibration data report 3 years (requires opt. c3). opt. d5 calibration data report 5 years (with opt. c5). opt. r3 repair service 3 years. opt. r5 repair service 5 years. acquisition memory options tds6000b models: 2m? 8 m samples on all channels. 3m 16 m samples on all channels. 4m 32 m samples on all channels. tds6000c models: 2m 16 m samples on two channels; 8 m samples on all channels. 3m 32 m samples on two channels; 16 m samples on all channels. 4m 64 m samples on two channels; 32 m samples on all channels. software options cp2 *1 tdscpm2 ansi/itu telecom pulse compliance testing software (requires opt. sm). dvd tdsdvd optical storage analysis. dvi tdsdvi dvi compliance test solution. et3 tdset3 ethernet compliance test software. ht3 hdmi compliance test software. ja3 tdsjit3 v2.0 advanced jitter analysis software. je3 tdsjit3 v2.0 essentials jitter analysis software. j2 tdsddm2 disk drive analysis software. pw3 *2 tdspwr3 power measurement and analysis software. rte tdsrt-eye serial data compliance and analysis software. rja software bundle of tdsjit3 v2.0 (opt. j3a), tdsrt-eye (opt. rte), and protocol trigger decode (opt. ptd). rsa software bundle of tdsjit3 v2.0 (opt. j3a), rt-eye (opt. rte), serial trigger (opt. st), protocol trigger and decode (opt. ptd) and serial mask testing (opt. sm). pce *3 pci express compliance module for opt. rte. ptd protocol trigger and decode (provides protocol decode on all models, requires opt. st for protocol triggering on the tds6000c series only). iba *3 infiniband compliance module for opt. rte. sm serial communications mask testing (enables hardware clock recovery). sst sata and sas analysis software module for opt. rte. st serial pattern trigger (enables hardware clock recovery) usb *4 tdsusbs usb 2.0 compliance test s/w only. recommended accessories p7313 12.5 ghz differential probe. p7380 8 ghz differential probe. p7380sma 8 ghz differential probing system. aftds telecom differential electrical interface adapter (for line rates <8 mb/sec; requires tca-bnc adapter). keyboard (usb interface) full-size keyboard with 4 port usb hub order 119-6297-00. transit case order 016-1942-00. tekconnect adapters tca-1meg: tekconnect high-impedance buffer amplifier. includes p6139a passive probe. tca-sma: tekconnect-to-sma adapter. tca-n: tekconnect-to-n adapter. tca-bnc: tekconnect-to-bnc adapter. tca75: 4 ghz precision tekconnect 75 ? to 50 ? adapter with 75 ? bnc input connector. oscilloscope cart order k4000. software wstro: wavestar waveform capture and documentation software. test fixtures tdsusbf: tdsusb test fixture for use with opt. usb. *1 requires option sm. *2 option 3m and a tca-1meg tekconnect 1 m ? buffer ampli- fier are recommended for use with this software. *3 requires option rte (serial data compliance and analysis). *4 requires option tdsusbf (usb test fixture). digital storage oscilloscopes ?www.tektronix.com/oscilloscopes 10
digital storage oscilloscopes ?www.tektronix.com/oscilloscopes 11 digital storage oscilloscope tds6000 series after purchase upgrades of tds6000b and tds6000c series oscilloscopes to upgrade your oscilloscope, order option as noted. acquisition record length: current record length desired order standard 8 msamples (16 msamples tds6000c) tds6bup opt. m02 16 msamples (32 msamples tds6000c) tds6bup opt. m03 32 msamples (64 msamples tds6000c) tds6bup opt. m04 8 msamples 16 msamples (32 msamples tds6000c) tds6bup opt. m23 32 msamples (64 msamples tds6000c) tds6bup opt. m24 16 msamples 32 msamples (64 msamples tds6000c) tds6bup opt. m34 desired option order serial comm mask testing tds6bup opt. sm serial pattern trigger tds6bup opt. st hardware clock recovery for serial data stream included in opt. sm and opt. st analysis and compliance software ansi/itu telecom pulse compliance tds6bup opt. cp2 (requires opt. sm) dvd optical storage analysis tds6bup opt. dvd dvi compliance test tds6bup opt. dvi ethernet compliance tds6bup opt. et3 jit3 v2.0 advanced jitter analysis software tds6bup opt. ja3 jit3 v2.0 essentials jitter analysis software tds6bup opt. je3 ddm2 disk drive analysis software tds6bup opt. j2 power measurement/analysis tds6bup opt. pw3 protocol trigger and decode (trigger capability tds6bup opt. ptd for tds6000c only, requires opt. st) rt-eye serial data compliance and analysis software tds6bup opt. rte pci express compliance module for opt. rte tds6bup opt. pce (requires opt. rte or rja or rsa) infiniband compliance module for opt. rte tds6bup opt. iba (requires opt. rte or rja or rsa) usb 2.0 compliance, software only tds6bup opt. usb (requires tdsusbf test fixture) rt-eye serial data analysis software and tdsjit3 v2.0 tds6bup opt. rja advanced jitter analysis, protocol debug software bundle rt-eye serial data analysis, tdsjit3 v2.0 advanced jitter tds6bup opt. rsa analysis, opt. sm serial mask, opt. st serial trigger, opt. ptd protocol trigger and decode software bundle
digital storage oscilloscope tds6000 series our most up-to-date product information is available at: www.tektronix.com copyright ? 2004, tektronix, inc. all rights reserved. tektronix products are covered by u.s. and foreign patents, issued and pending. information in this publi- cation supersedes that in all previously published material. specification and price change privileges reserved. tektronix and tek are registered trademarks of tektronix, inc. all other trade names referenced are the service marks, trade- marks or registered trademarks of their respective companies. 12/04 hb/wow 55w-14873-6 contact tektronix: asean / australasia / pakistan (65) 6356 3900 austria +41 52 675 3777 balkan, israel, south africa and other ise countries +41 52 675 3777 belgium 07 81 60166 brazil & south america 55 (11) 3741-8360 canada 1 (800) 661-5625 central east europe, ukraine and baltics +41 52 675 3777 central europe & greece +41 52 675 3777 denmark 80 88 1401 finland +41 52 675 3777 france & north africa +33 (0) 1 69 81 81 germany +49 (221) 94 77 400 hong kong (852) 2585-6688 tektronix (india) private limited (91) 80-22275577 italy +39 (02) 25086 1 japan 81(3)6714-3010 luxembourg +44 (0) 1344 392400 mexico, central america & caribbean 52 (55) 56666-333 middle east, asia and north africa +41 52 675 3777 the netherlands 090 02 02797 norway 800 16098 peoples republic of china 86 (10) 6235 1230 poland +41 52 675 3777 portugal 80 08 12370 republic of korea 82 (2) 528-5299 russia, cis & the baltics 7 095 775 1064 south africa +27 11 254 8360 spain (+34) 901 988 054 sweden 020 08 80371 switzerland +41 52 675 3777 taiwan 886 (2) 2722-9622 united kingdom & eire +44 (0) 1344 392400 usa 1 (800) 426-2200 usa (export sales) 1 (503) 627-1916 for other areas contact tektronix, inc. at: 1 (503) 627-7111 last updated 1 november, 2004 p roduct(s) are manufactured in iso registered facilitie s. dpo ?digital phosphor technology you have to see it to believe it. a digital phosphor oscilloscope (dpo) is ideal for those who need the best design and troubleshooting tool for a wide range of applications, for communication mask testing, digital debug of intermittent signals, repetitive digital design and timing applications. covering a spectrum of bandwidth from 100 mhz to 7 ghz, tektronix offers a wide selection of dpos for you to see a world others don?. openchoice provides more choices for your networking and analysis solutions. openchoice is a collection of software libraries, utilities, samples, industry-stan dard protocols and interfaces offered with many tektronix oscilloscopes and logic analyzers. from 60 mhz to 15 ghz, open choice allows you to communicate with your oscilloscope or logic analyzer over a network, using numerous connectivity protocols and physical interfaces, such as gpib, ethernet, rs-232 and shared memory. tekconnect superior signal fidelity and unparalleled versatility at your fingertips. tekconnect interface takes probe intelligence to the next level whether you are measuring high voltage, current, power, or even micro-volt level signals. the tekconnect interface ensures superior signal fidelity with useful bandpass up to 18 ghz at the oscilloscope input, while offering unparalleled versatility. with the tekconnect interface, you can be assured that maximum signal integrity is maintained to meet your present and future bandwidth needs. oscilloscope software turn your general purpose oscilloscope into a highly specialized analysis tool. tektronix offers exceptional application solutions that instill your oscilloscope with specific technology or procedure expertise, vastly simplifying the development and testing of specialized designs. from serial da ta standards to power measurements, tektronix has the broadest selection of oscilloscope software to convert your oscilloscope into a highly specialized and power analysis tool.


▲Up To Search▲   

 
Price & Availability of TDS6804B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X